- Detachable exposure release switch with a cord of 5 meters - Light weight, compact, easily transportable - Digital mobile radiographic unit with telescopic arm - Suitable for bedside X-ray forward patients - Intensive care units and operation theatres - Digital system with flat panel detector
specifications
X-ray Generator
1. Microprocessor controlled high frequency 2. Maximum Output Power: 50 kW 3. Input Power Supply: 220VAC single phase 4. Output Voltage: 40-150kV 5. Tube Current Range: 10-630mA 6. Exposure Time Range: 1ms-10000ms 7. mAs Range: 0.1mAs-250mAs mAs 8. APR Parameter Guidance APR 9. Fault Self-diagnosis and Display
X-ray tube
1. Focus Design: 0.6mm/1.2mm 2. Nominal Electric Power: 50kW (50Hz) 3. Maximum kV: 150kV 4. Anode Target Angle: 12° 5. Anode rotation:3200rpm 6. Anode head storage capacity:300KHU 7. Collimation:multi-leafrotatable ±90 degrees with off/on timer
Flat Panel Detector
1. Detector Type: TFT amorphous silicon flat panel detector 2. Detector Panel Size: 430mm x 430mm 3. Effective Imaging Size of Detector: 17x17 inches 4. Pixel Matrix for Data Acquisition: ≥3072x3072 5. Pixel Spacing of Detector: ≤139 um 6. Spatial Resolution of Detector: ≥3.4LP/MM 7. Gray Scale of Pixel: 17Bit 8. Image Acquisition and Transmission Time: 3s 9. Weight: 4.0kg
Image acquisition/processing and diagnostic workstation software functions
1. English interface, standard DICOM3.0 image 2.Specialized image acquisition control software package, specialized part protocol processingsoftware package
Workstation 1. CPU: Intel i7, above 3GHz; CPU 2. Host memory: ≥ 8GB DDR3 1600 high-speed memory 3. Hard drive: high-capacity high-speed hard drive 1T/7200rpm 4. Workstation monitor: touch screen 5. Communication network card and interface: 1000M network card, 1000M network interface, Jumbo Frame: 9K 7. DICOM3.0 interface 8. Image printing: DICOM printing, paper printing, manual selection and printing of displayed images, single key selection and marking of image printing, selection of different printing devices, film formats and number of prints, print queue control, stop/start of pre-set settings 10. User personalization settings:Display format and layout, default value settings, toolbar settings, part protocol enhancement filters; 11. Image display: The display configuration supports 1920 × 1080 and high-definition display.
Battery
1. Brand:CATL 2. Type of battery:lithium 3. Battery quantity:1 pcs 4. Voltage capacity:48V55ah 5. Battery provide power for the motor to move the machine
Charges
1. Input voltage range:220-240V,50Hz,Single phase 2. Charging time for battery:2 hours
Console
1. Touch screen:19inch 2. Size:301mm*376nmm 3. Image storage memory:Minimum 1 TB (4000 image storage) 4. Touch screen console view image and provide post processing